Communications Specifications Settings

You must set the output handshaking and output controls for EtherNet/IP communications.
IMPORTANT
• Set the Communications Module to EtherNet/IP in the startup settings before setting the communications specifications.
Reference:
Communications Module Settings (Startup Settings) (p.62)
After you select the Communications Module, save the settings to the Sensor Controller and restart the Sensor
Controller. If you do not restart the Sensor Controller, the selected Communications Module will not be enabled.
Furthermore, if the operation mode is set to the Multi-line Random Trigger Mode, the Communications Modules for lines
1 and higher must also be set to EtherNet/IP.
• When using Multi-line Random-trigger Mode, specify different addresses for the sending and receiving areas for each
line.
• After the tag data link is set, the Sensor Controller automatically restarts to reflect the setting.
Setting IP Addresses
Use the following procedure to set the IP address of the Sensor Controller.
1
On the Main Window, select [Tool] − [System Settings].
2
In the tree view on the left, select [System Settings] − [Communication] − [Ethernet Normal
(xyz)]. ("xyz" depends on the Communications Module.)
The Ethernet View is displayed.
3
Set up the following items.
UDP
222
Communicating with EtherNet/IP
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)