SYSDATA
Acquires settings related to logging
Acquires settings related to current logging.
<Command format>
<Response format>
When processing is performed normally
When processing is not performed normally
<Parameters explanation>
Data
Image logging
Folder name of image logging save
destination
Prefix for image logging file name
Data logging
Name of destination folder for saving
data logging
IMPORTANT
The save destination folder differs depending on the Sensor Controller model.
When you use FH series/FZ5-1100 series, do not save to the any folder except RAMDisk and external memory device
(such as C:\ProgramFiles\FZ).
It is possible not to perform correctly due to the decrease of Scene data storage region.
Save destination
RAMDisk
C:\Data\RAMDisk
External memory
E:\, F:\, G:\, H:\, M:\ (FH series only)
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
Identifier
imageLogging
imageLoggingDirectory
imageLoggingHeader
dataLogging
dataLoggingDirectory
FH series/FZ5-1100 series
Setting value
0: None
1: Only NG
2: All
Save destination folder name (one-byte
alphanumeric character)
Prefix for image logging file name (one-byte
alphanumeric characters)
0: None
1: Only NG
2: All
Save destination folder name (one-byte
alphanumeric character)
FZ5-L series/FZ5-600 series
\RAMDISK
\USBDisk to \USBDisk3
3