Setting item
Address setting 2
Address Settings is only for the following series:
• FH-1000 series (2 camera type)
• FH-3000 series (2 camera type)
• FH-L series Sensor Controller
• Obtain an IP address automatically
• [Use the following IP address]
IP address
Subnet mask
Default gateway
DNS server
Preferred WINS
server
Alternate WINS
server
4
Click [Apply] to apply the settings.
Click [Close] to close the System Settings Dialog Box .
IMPORTANT
Change the IP address and subnet mask for [Address setting] and [Address setting 2] as required so that each designate a
different network address. If the same network address is specified, communications may not be performed correctly.
Set the EtherNet/IP Output Specifications
1
On the Main Window, select [Tool] − [System Settings].
2
Select [System Settings] and then select [Communication] − [EtherNet/IP].
The Ethernet View is displayed.
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
Set value
[Factory default]
Set the IP address of the bottom Ethernet port on the Sensor
Controller.
a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
d: 2 to 254
[10.5.6.100]
0.0.0.0 to
255.255.255.255
[255.255.255.0]
Same as [Address setting].
a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
d: 0 to 255
[10.5.6.100]
a.b.c.d
a: 1 to 223
b: 0 to 255
c: 0 to 255
d: 2 to 255
[10.5.6.100]
a.b.c.d
a: 1 to 223
b: 0 to 255
Inputs address of WINS server.
c: 0 to 255
d: 0 to 255
[0.0.0.0.]
a.b.c.d
a: 1 to 223
b: 0 to 255
Inputs address of WINS server.
c: 0 to 255
d: 0 to 255
[0.0.0.0]
Description
Communicating with EtherNet/IP