Omron FH series User Manual page 188

Hide thumbs Also See for FH series:
Table of Contents

Advertisement

Registering the Items To Output
Set expressions for the data to output.
1
Click the [Data Output] icon (
2
In the Item Tab Area, click [Setting].
3
In the list, select the output data number for the expression to set.
The selected output data number is displayed under the list.
4
Click the [...] button next to the expression box and set the expression.
Specify the processing items, measurement results, and measurement data in the expression.
You can also perform arithmetic or function calculations on the measurement data before it is output.
For calculation settings, refer to section of Calculation in FH/FZ5 Processing Item Function Reference
Manual (Cat. No. Z341).
5
Click the [...] button for the [Comment] box and enter an explanation of the expression.
The comment you enter will be displayed in the detailed results on the Main Window.
For example, if you enter "Test" as the comment for expression 0, "Test" will be displayed in place of
"Expression 0" in the detailed results area on the Main Window.
6
To output more than 9 items, click on the [...] under [Number of output data items] and change
the number of output items for the set Output Unit.
By default you can output only 8 items, but you can change this to output a maximum of 256 output data
items (1,024 bytes).
7
Repeat steps 4 and 5 to set expressions for all of the required output data numbers.
186
Communicating with PLC Link
) in the measurement unit list (flow).
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)