Omron FH series User Manual page 380

Hide thumbs Also See for FH series:
Table of Contents

Advertisement

Getting Image Display State
Gets the image mode for the specified image display window.
Command (PLC to Sensor Controller)
First word in
Command
Command Area
code
+2
5030
+3
0020
+4
-
+5
-
Response (Sensor Controller to PLC)
First word in
Command
Response Area
code
+2
5030
+3
0020
+4
-
+5
-
+6
-
+7
-
Getting Communication Input State
Gets the input state (permitted/prohibited) for communication modules.
Command (PLC to Sensor Controller)
First word in
Command
Command Area
code
+2
7010
+3
0020
+4
-
+5
-
378
Command Control
Bit
12 to 15
8 to 11
4 to 7
0101
0000
0011
0000
0000
0010
0000
0000
0000
0000
0000
0000
Bit
12 to 15
8 to 11
4 to 7
0101
0000
0011
0000
0000
0010
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
Bit
12 to 15
8 to 11
4 to 7
0111
0000
0001
0000
0000
0010
0000
0000
0000
0000
0000
0000
0 to 3
0000
Command code
0000
0000
Display image window number
FH: Image display window number (0 to 23)
FZ5:
Displaying 1 image: 1
0000
Displaying 2 images: 1 and 2
Displaying 4 images: 1 to 4
Displaying thumbnails: 0 to 4
0 to 3
0000
Command code
Response target command codes
0000
0000
Response code
Command execution result
OK: 0(0000 0000)
0000
NG: Not 0 (0000 0000)
0000
Response data
Image mode
0: Through
0000
1: Freeze or Freeze and Last NG together
2: Last NG
0 to 3
0000
Command code
0000
0000
Communication module types
0: Serial (Ethernet)
1: Serial (RS-232C/422)
2: Parallel I/O
0000
3: Fieldbus
4: Remote operation
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
Description
Description
Description

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fz5 series

Table of Contents