Response (Sensor Controller to PLC)
First word in
Command
Response Area
code
+2
7020
+3
0030
+4
-
+5
-
Set Parallel Terminal Status
Sets the specified parallel I/O terminal: ON/OFF
Specifies the Parallel terminal with a combination of terminal type, terminal number and terminal status.
For how to set, refer to the following:
Example)
When you want to set the OR3 of Line3 status.
1. Set [6] in terminal type, [OR] is specified.
2. Set [3] in terminal number, [OR3] is specified.
3. Set [1] in terminal status, [OR3] terminal is specified to turn ON from OFF.
4. Send the specified command which set the above step 1 to 3 to the port number of Line 3.
5. Executed result of command is responsed.
Command (PLC to Sensor Controller)
First word in
Command
Command Area
code
+2
8010
+3
0030
+4
-
+5
-
+6
-
+7
-
+8
-
+9
-
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
Bit
12 to 15
8 to 11
4 to 7
0111
0000
0010
0000
0000
0011
0000
0000
0000
0000
0000
0000
Bit
12 to 15
8 to 11
4 to 7
1000
0000
0001
0000
0000
0011
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0 to 3
0000
Command code
Response target command codes
0000
0000
Response code
Command execution result
OK: 0(0000 0000)
0000
NG: Not 0 (0000 0000)
0 to 3
0000
Command code
0000
0000
Terminal type:
Set the terminal by combining Terminal number.
Specified terminal differ according to the Sensor
0000
Controller series. For detail, refer to
0000
Terminal number:
Set the terminal by combining Terminal type.
Specified terminal differ according to the Sensor
0000
Controller series. For detail, refer to
0000
Terminal status:
Set the specified terminal status. (0: OFF/1: ON)
0000
Description
Description
*1
.
*1
.
Command Control
3
395

Advertisement

Table of Contents
loading