Outputting the STGOUT and SHTOUT Signals
These functions are supported by the FH-series Sensor Controllers only.
With parallel communications, the STGOUT signal (strobe trigger output) and SHTOUT signal (shutter
output) cannot be output at the same time.
Select which signal to output based on your needs.
1
On the Main Window, select [System Settings] − [Camera] − [Output Signal Setting] from the
[Tool] menu.
The output signal settings dialog box is displayed.
2
Select the signal to output in the [Common] area.
Setting item
Output signal
Note
• In Multi-line Random-trigger Mode, this output signal selection can be used to set the output signal for line 0 only. The
setting for line 0 will be used for all other lines.
• The STGOUT signal output settings must be set in the [Electronic flash setting] for each Camera Image Input processing
item.
IMPORTANT
SHTOUT signals output through EtherCAT communications are not affected by this setting.
306
Parallel Communications
Setting value
[Factory default]
Uses the STGOUT signal line as the STGOUT signal.
[STGOUT]
When STGOUT is selected, the SHTOUT signal cannot be used.
Uses the STGOUT signal line as the SHTOUT signal.
SHTOUT
When SHTOUT is selected, the STGOUT signal cannot be used.
Description
Vision System FH/FZ5 Series User's Manual