Omron FH series User Manual page 336

Hide thumbs Also See for FH series:
Table of Contents

Advertisement

Multi-line Random Trigger Mode
FH
Data
Performs measure-
Continuous
ment continuously while
Measurement
command is being
input.
Changes the measure-
Select Scene
ment scene.
Set Scene
Changes the measure-
Group
ment scene groups.
Clears measurement
Clear Mea-
values.
surement Val-
The OR signal and DO
ues
signal are not cleared.
Clears the error output.
Clear Error
The ERROR indicator is
also cleared.
Clear Parallel
Clears the OR signal
OR+DO
and DO signal.
Clears the wait state in
Wait State
the control flow parallel
Clear
processing unit.
*1:
Two lines: DILINE0
Three or four lines: DILINE0 and DILINE1
Five to eight lines: DILINE0 to DILINE2
*2:
Only the signals assigned to the line that the command was sent to can be cleared. The OR and DO signals are not cleared
for other lines. If the command is sent to a line that cannot use the DO signals, only the OR signal will be cleared.
334
Parallel Communications
(DI7 to DI0, DILINE0, DILINE1, and DILINE2)
Description
Execute
(DI7)
1
1
1
1
1
1
*2
1
Input format
Command
Command
information
(DI6, DI5)
(DI4 to DI0)
*****
The Controller
does not see
00
this signal, so a
setting of either
0 or 1 makes no
difference.
Input [Scene
01
No.] in binary
format (0 to 31).
Input [Scene
Group No.] in
11
binary format (0
to 31).
10
00000
10
00001
10
00010
10
01111
Vision System FH/FZ5 Series User's Manual
Input example (DILINE2
to DILINE0, DI7 to DI5,
and DI4 to DI0)
*1
Line number
Continuous mea-
surements on line 1
when 2 lines are
used
Input example:
0 100 00000
Specify the line
Changing to scene 2
number to send
on line 2 when 4
the command to.
lines are used
Input example:
• Two lines: 0 or
10 101 00010
1
Changing to scene
group 3 on line 6
• Three or four
when 8 lines are
lines:
used
00 (line 0)
Input example:
01 (line 1)
110 111 00011
10 (line 2)
11 (line 3)
Clearing the mea-
surement results for
• Five to eight
line 1 when 2 lines
lines:
are used
000 (line 0)
Input example:
001 (line 1)
1 110 00000
010 (line 2)
Clearing the error
011 (line 3)
status for line 1
100 (line 4)
when 4 lines are
101 (line 5)
used
110 (line 6)
Input example:
111 (line 7)
01 110 00001
Clearing the OR and
DO signals for line 2
when 8 lines are
used
Input example:
010 110 00010
11001111
for Communications Settings (Z342)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fz5 series

Table of Contents