Omron FH series User Manual page 221

Hide thumbs Also See for FH series:
Table of Contents

Advertisement

Output tag set
Output tags
(1) Command Area
Input
connection to
You write the following control
the Sensor
commands for the Sensor
Controller
Controller.
• Control inputs
• Command code
• Command parameters
(2) I/O ports in the
User Input Area
Write the data defined by
User to Sensor Controller.
Input tag set
Input tags
(3) Response Area
The Sensor Controller writes
the execution results to the
PLC.
Output
connection to
PLC
(4) Data Output Area
The Sensor Controller writes
the output data to the PLC.
(5) I/O ports in the
User Output Area
Output
connection to
Write the data defined by
PLC
User to Sensor Controller.
*1:
The Response Area (3) and Data Output Area (4) are assigned to continuous memory addresses or to variables.
*2:
You can use output controls (handshaking) to prevent output data from being externally output from the communications buffer
until the Controller (master) turns ON the DSA signal to request the output data.
*3:
Refer to
Settings Required for Data Output (p.29) for information on the Output Units that output measurement data.
*4:
Use the Macro Customization Function to input and output to the User Area.
For the Macro Customization Function, refer to
FZ5 Macro Customize Functions Programming Manual (Cat. No. Z367).
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
PLC
Input tag set
Commands
Input
Output tag set
*1
Responses
External
*2
outputs
The FH Sensor Controller writes the values measured by processing item.
Output
EtherNet/IP communication of the IO Module List in the Vision System FH/
FH Sensor Controller
The control commands that
are written to the Command
Area are executed.
Sensor Controller process
using the written data.
*4
Execution
Measurement results are written to
the Response Area of the PLC.
• Control outputs
• Command code
• Response code
• Response data
Measurement flow
Execution of
processing item
Commu-
nications
Module
Execution of processing
item for the Output Unit.
Data is written to the
Communications Module.
Sensor Controller writes the
data defined by User to the
I/O ports in the User Output
Area.
*4
...
Responds
when a
command is
received.
20 bytes
32 bytes
...
Responds when
a command is
received.
16 bytes
...
Operations are
performed by executing
the measurement flow.
32 bytes
*3
32 bytes
Communicating with EtherNet/IP