Settings Required for Data Output
Use the following procedure to set up Output Unit processing units for data output.
Measurement Data
1
Place the output data in the processing flow.
Place the processing unit for data output in the measurement flow.
Processing Units That Serve as Output Units
The processing items under [Output result] in the processing item tree in the Flow Editor serve as Output
Units.
Output Unit Selection
Select the Output Units according to the communications protocol based on the combinations that are
shown in the following table.
For information on communications protocols, refer to
with the Sensor Controller (p.19).
OK: Data can be output, ---: Data cannot be output.
Output unit
Parallel Data Output
Parallel Judgement Output
Data Output
Fieldbus Data Output
2
Set the items to output.
Set the items to output as output data in the Output Units that you have placed in the measurement flow.
Refer to the descriptions for the communications protocol for the specific procedures to set the output
items in the Output Units.
Character Output (PLC Link Non-procedure Communications Only)
Set the character output settings for processing items that read output characters, such as Character
Inspection.
The character output operation is executed by the above processing items. In this case, it is not necessary to
set an Output Unit in the measurement flow.
Refer to the descriptions for individual processing items for details on the settings required for character
output.
• Character Inspection (Refer to
Reference Manual (Cat. No. Z341).)
• Barcode (Refer to
Z341).)
• 2DCode (Refer to
Z341).)
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
Parallel
OK
OK
---
---
Character Inspection in the Vision System FH/FZ5 Series Processing Items
Barcode in the Vision System FH/FZ5 Series Processing Items Reference Manual (Cat. No.
2DCode in the Vision System FH/FZ5 Series Processing Items Reference Manual (Cat. No.
Communication Protocols for Communication
Communications protocol
PLC Link
EtherNet/IP
---
---
---
---
OK
---
---
OK
Control Methods Using an External Device
Non-
EtherCAT
procedure
---
---
---
---
---
OK
OK
---