• Communicating with a Mitsubishi Electric PLC
(When [PLC Link (MELSEC/QnU/Q/QnAS)] is selected for the Communications Module)
Setting item
Command area
Area
Address
Response area
Area
Address
Data output area
Area
Address
Output control
Asynchro-
nous output
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
Set value
[Factory default]
• [Data register]
• File register
Set the Command Area.
• Link register
0 to 99999
Set the first word address in the Command Area.
[0]
• [Data register]
• File register
Set the Response Area.
• Link register
0 to 99999
Set the first word address in the Response Area.
[100]
• [Data register]
• File register
Set the Data Output Area.
• Link register
0 to 99999
Set the first word address in the Data Output Area.
[200]
Set whether to provide an interlock with the PLC when per-
forming data output.
• None
None: Data is output regardless of the status of signals from
• [Handshaking]
the PLC. GATE is always OFF.
Handshaking: Data is output after confirming DSA from the
PLC.
Selected: Measurement processing and data output process-
ing are performed in parallel.
The data output processing does not affect the processing time
of the measurement flow.
• Selected.
• [Not selected.]
Not selected: Measurement processing and data output process-
ing are synchronized so that all data output processing is finished
when measurements are finished.
This increases the overall processing time of the measurement
flow.
Reference:
Description
IMPORTANT
Always set the output control to [Handshaking] for
asynchronous output. If you set the output control to
[None], operation will be fixed at the following values:
Output time: 100 ms, Output period: 200 ms.
If you need a shorter output time and output period when
the output control is set to [None], do not select
asynchronous output.
Note
This is the same as the PLC Link operation of the FZ4
Vision Sensor.
Asynchronous Output (p.182)