SHTOUT Signal Settings: [Output Signal Setting]
These functions are supported by the FH-series Sensor Controllers only.
This setting sets the SHTOUT signal that is output when the Camera exposure is completed. By detecting
when the exposure is completed using the SHTOUT signal, you can minimize the amount of time that the
workpiece must be kept still for imaging and you can move the Camera or workpiece immediately after the
exposure is completed.
1
On the Main Window, select [System Settings] − [Camera] − [Output Signal Setting] from the
[Tool] menu.
The output signal settings dialog box is displayed.
2
Set the SHTOUT signal for each line in the [Line settings] area.
Setting item
SHTOUT delay [μs]
SHTOUT width [μs]
SHTOUT polarity
3
Click [Apply].
IMPORTANT
• If more than one Camera is connected, the SHTOUT signal will remain ON for the Camera with the longest exposure
time.
• You cannot use the Shutter Output Signal when the image mode is set for a through image.
• If you have registered more than one Camera Image Input processing unit in the measurement flow, the SHTOUT signal
will be turned ON for each Camera Image Input processing unit individually.
• The SHTOUT signal will be output for as many times as imaging is performed when Camera Image Input HDR or
Camera Image Input HDR Lite processing item is used.
• The SHTOUT signal that is output through EtherCAT communications is affected by this setting.
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
Setting value [Factory
default]
0 to 1000 [0]
40 to 10000 [5000]
• [Positive]
• Negative
Description
Set the delay time until the SHTOUT signal turns
ON after exposure is completed in 10 μs incre-
ments.
Set the SHTOUT signal output time in 10 μs incre-
ments.
Set the pulse polarity of the SHTOUT signal.
Positive: The SHTOUT signal turns ON when expo-
sure is completed.
Negative: The SHTOUT signal turns OFF when
exposure is completed.