Event name
Initial scene group error
Meaning
Initial scene group setting is incorrect.
Source
EtherCAT Master Function Module
Error attributes
Level
Effects
User program
EtherCAT NET RUN
Indicators
Variable
System-defined
variables
None
Assumed cause
The external storage specified as the
scene group destination by the Scene
Group Saving Destination Settings tool
is not connected at the time of startup.
Cause and
correction
The destination directory is not
detected at the time of startup.
Initial scene group number is not within
the range of scene group accepted by
the system.
Attached
None
information
Precautions/
None
Remarks
Event name
Initial scene number error
Meaning
Initial scene number setting is incorrect.
Source
EtherCAT Master Function Module
Error attributes
Level
Effects
User program
EtherCAT NET RUN
Indicators
Variable
System-defined
variables
None
Assumed cause
Cause and
Initial scene number is not within the
correction
range of scenes accepted by the sys-
tem.
Attached
None
information
Precautions/
None
Remarks
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
Source details
Minor fault
Recovery
Continues.
Operation
EtherCAT NET ERR
---
Data type
Correction
Connect the specified external stor-
age.
Select other directory in the connected
external storage under the Scene
Group Saving Destination Setting sec-
tion on the Scene Group Saving Desti-
nation Settings dialog box.
Correct the initial scene group number,
save, and restart the controller.
Source details
Minor fault
Recovery
Operation
Operation
EtherCAT NET ERR
---
Data type
Correction
Correct the initial scene number, save,
and restart the controller.
EtherCAT Connections (FH-1000 series/FH-3000 series only)
Event code
58230000 hex
Slave
Detection timing
Error reset (after
resetting the error
Log category
in the slave)
The whole slave operation suspends until a corrective
action is taken.
EtherCAT LINK/ACT
---
Name
---
Prevention
Confirm that the external storage is
connected, and restart the controller.
Use the external storage where the
specified destination directory is.
Confirm that the initial scene group
number is correct, save, and restart
the controller.
Event code
58240000 hex
Slave
Detection timing
Error reset (after
resetting the error
Log category
in the slave)
The whole slave operation suspends until a corrective
action is taken.
EtherCAT LINK/ACT
---
Name
---
Prevention
Confirm that the initial scene number is
correct, save, and restart the control-
ler.
After turning ON
slave power
System
2
---
---
After turning ON
slave power
System
---
---
109