Communications Module Settings (Startup Settings)

The communication method used for communication with the Sensor Controller is selected from the
communication modules.
1
On the Main Window, select [Tool] − [System Settings].
2
Select [System settings] − [Startup] − [Startup setting] on the Multiview Explorer on the left
and then click [Communication].
3
Select one of the following Communications Modules based on the communications method
that is used to connect with the Sensor Controller and the Unit to connect to, then click
[Apply].
Communications Module
Serial (Ethernet)
Normal (UDP)
Normal (TCP)
Normal (TCP Client)
Normal (UDP)
(Fxxx series method)
Serial (RS-232C/422)
Normal
Normal
(Fxxx series method)
*1:
With the [Normal (Fxxx series method)] communications method, the OK response timing in relation to MEASURE
commands is different from that of the [Normal] communications method.
Reference:
Command Formats (p.289)
4
Click the [Data save] button in the Toolbar.
5
On the Main Window, select [Function] − [System restart].
Click [OK] in the [System restart] dialog box to restart the Sensor Controller.
6
When the Sensor Controller has restart, operation will be performed for the default settings of
the specified Communications Module.
Set the IP address and other settings for the PLC or other external device.
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
Performs non-procedure communications through an Ethernet connection.
Select this Communications Module to communicate with the external device with
UDP communications.
Select this Communications Module to communicate with the external device with
TCP server communications.
Select this Communications Module to communicate with the external device as a
TCP client.
Select this Communications Module to communicate with the external device
*1
through UDP or Fxxx-series
Normally select this Communications Module to use non-procedure communica-
tions through an RS-232C/422 connection.
Normally selected when performing non-procedure RS-232C/422 communications.
Select this Communications Module to communicate with the external device
*1
through Fxxx-series
communications.
Description
communications.
Non-procedure Communications
2
271