Image Logging Folder Name Setting
Sets the image logging folder name.
Command (PLC to Sensor Controller)
First word in
Command
Command Area
code
+2
4010
+3
0050
+4
-
+5
-
:
-
Response (Sensor Controller to PLC)
First word in
Command
Response Area
code
+2
4010
+3
0050
+4
-
+5
-
Data Logging Folder Name Setting
Sets the data logging folder name.
Command (PLC to Sensor Controller)
First word in
Command
Command Area
code
+2
4020
+3
0050
+4
-
+5
-
:
-
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
Bit
12 to 15
8 to 11
4 to 7
0100
0000
0001
0000
0000
0101
0000
0000
0000
0000
0000
0000
0000
0000
0000
Bit
12 to 15
8 to 11
4 to 7
0100
0000
0001
0000
0000
0101
0000
0000
0000
0000
0000
0000
Bit
12 to 15
8 to 11
4 to 7
0100
0000
0010
0000
0000
0101
0000
0000
0000
0000
0000
0000
0000
0000
0000
0 to 3
0000
Command code
0000
0000
Name of the image capture folder with the
0000
absolute path
Up to 230 characters
0000
0 to 3
0000
Command code
Response target command codes
0000
0000
Response code
Command execution result
OK: 0(0000 0000)
0000
NG: Not 0 (0000 0000)
0 to 3
0000
Command code
0000
0000
Name of the data logging folder with the absolute
0000
path.
Up to 247 characters
0000
Description
Description
Description