Omron FH series User Manual page 353

Hide thumbs Also See for FH series:
Table of Contents

Advertisement

Specifying Character Strings
Specify the ASCII character code for every two bytes.
In this example, the inputs are given to save the image data for image data 1 to a destination specified by the
absolute path (USBDisk\IMG01\LABEL.IFZ) with the Save Image command.
First word in Command Area
+2 and +3 words
+4 and +5 words
+6 to +17 words
• OMRON or Yaskawa Electric PLCs
Command (PLC to Sensor Controller)
First word in
Hexadecimal
Command Area
+2
4000
+3
0070
+4
0001
+5
0000
+6
5553
+7
4244
+8
6973
+9
6b32
+10
5c49
+11
4d47
+12
3031
+13
5c4c
+14
4142
+15
454c
+16
2e49
+17
465a
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
Command code (4000 0070 hex)
Image data number 1 (0000 0001 hex)
Save destination (USBDisk\IMG01\LABEL.IFZ)
notation
12 to 15
8 to 11
0100
0000
0000
0000
0000
0000
0000
0000
0101
0101
0100
0010
0110
1001
0110
1011
0101
1100
0100
1101
0011
0000
0101
1100
0100
0001
0100
0101
0010
1110
0100
0110
Description
Bit
4 to 7
0 to 3
0000
0000
Command code
0111
0000
0000
0001
Image data No.
0000
0000
0101
0011
0100
0100
Destination
0111
0011
+6: 5553(US)
+7: 4244(BD)
0011
0010
+8: 6973(is)
0100
1001
+9: 6b32(k2)
+10: 5c49(\I)
0100
0111
+11: 4d47(MG)
0011
0001
+12: 3031(01)
+13: 5c4c(\L)
0100
1100
+14: 4142(AB)
0100
0010
+15: 454c(EL)
0100
1100
+16: 2e49(.I)
+17: 465a(FZ)
0100
1001
0101
1010