Omron FH series User Manual page 299

Hide thumbs Also See for FH series:
Table of Contents

Advertisement

Outputting Binary Data
Set the output format as [Binary] in [Output form] of the [Data Output] processing item.
Output Format
The measurement data is multiplied by 1000 and output is continuous with 4 bytes per data item.
Negative numbers are output in 2's complement format.
2's Complement
Refer to
Definitions of Basic Terms in the Vision System FH/FZ5 Series User's Manual (Cat. No. Z365).
Example: When Data 0 is "256.324", and data 1 is "-1.000"
Note
Unlike ASCII output, binary output has no separators between data, such as field separators or record separators.
Refer to
Output Format (Data Output) (p.282)
The range of values that can be output is as follows:
−2147483.648 ≤ Measurement value ≤ 2147483.647
When measurement value < −2147483.648, "−2147483.648" is output.
When measurement value > 2147483.647, "2147483.647" is output.
When JG (Judgement) is set, the next values are output.
OK: 1000 (1 × 1000)
NG: −1000 (−1 × 1000)
Note
After the measurement is completed, data output will not stop until all of the data is output. Data output will not be
interrupted.
Vision System FH/FZ5 Series User's Manual
for Communications Settings (Z342)
Non-procedure Communications
2
297

Advertisement

Table of Contents
loading