SCNSAVE
Saves scene data.
<Command format>
S C N S A V E
<Response format>
When processing is performed normally
When processing is not performed normally
<Parameters explanation>
Scene number
Destination
*1:
Do not specify a save destination other than RAMDisk or External memory.
The saved Scene data area may be reduced and the Sensor Controller will not perform correctly.
IMPORTANT
• If the specified file name already exists, this existing file will be overwritten.
• Do not turn off power of the Sensor Controller until return the response.
• For the FH/FZ5-1100 series, do not save to a non-volatile area on the C drive (such as C:\ProgramFiles\FZ).
This would reduce the storage area for scene data etc. and make correct operation impossible.
(Example)
When you save the following case:
• Scene number: 3
• SCNSAVE file name: LABEL1.SCN
• Drive name: USBDisk2
• Folder name of the external memory: IMG01
<Command>
<Response>
502
Command Control
C
R
Save destination
Scene No. (3 digits max.)
Specify the Scene number to save. (0 to 127)
The name of the file containing the Scene data you wish to save.
Specify the file name as an absolute path.
The file name needs the "SCN" extension.
Save destination folder differ depending on the Sensor Controller series.
Save destination
FH series/FZ5-1100 series
RAMDisk
C:\Data\RAMDisk
External memory
E:\, F:\, G:\, H:\, M:\ (FH series only)
\
\
\
*1
FZ5-L series/FZ5-600 series
\RAMDISK
\USBDisk to \USBDisk3
Vision System FH/FZ5 Series User's Manual