Generator - Daewoo MATIZ Service Manual

Table of Contents

Advertisement

DAEWOO M-150 BL2

GENERATOR

Removal Procedure
1. Disconnect the negative battery cable.
2. Disconnect the harness connector.
D Remove the battery harness connector nut to dis-
connect the battery positive connector (1).
D Disconnect the generator harness connector (2).
D102E504
3. Remove the generator drive belt.
D Loosen the generator adjusting bolt (1).
D Remove the lower bracket-to-generator bolt and
nut (2).
D Separate the generator drive belt from the genera-
tor.
D102E505
4. Remove the engine mounting lower bracket.
D Remove the engine mounting lower bracket, at-
taching reaction rod bolt and nut (1).
D Remove the engine mounting lower bracket bolts
(2).
D Remove the engine mounting lower bracket (3).
D102E506
5. Remove the generator.
D Remove the generator adjusting bolt (1).
D Carefully remove the genrator (2).
D102E507