EVAPORATOR TEMPERATURE SENSOR CIRCUIT (CONTINUED)
7.
READ A/C HEATER CONTROL MODULE DTC'S WITH DRB III
Turn the ignition off.
Reconnect the Evaporator Temperature Sensor connector.
Turn the ignition on.
With the DRB III , read A/C Heater Control Module DTC's.
Wait two minutes.
With the DRB III , read A/C Heater Control Module DTC's.
Does the DRB III display Evaporator Temperature Sensor Fail-
ure DTC?
Yes
>> Replace the Evaporator Temperature Sensor. (Refer to 24
- HEATING & AIR CONDITIONING/CONTROLS/EVAPO-
RATOR TEMPERATURE SENSOR - REMOVAL).
Perform BODY VERIFICATION TEST.
No
>> Go to 8
8.
READ A/C HEATER CONTROL MODULE DTC'S WITH DRB III
Ensure the Evaporator Temperature Sensor is connected at this time.
Start the engine.
Turn the A/C system on and run for at least five minutes (so water will
form on the Evaporator Temperature Sensor).
With the DRB III , read A/C Heater Control Module DTC's.
Does the DRB III
Failure DTC?
Yes
>> Replace the Evaporator Temperature Sensor. (Refer to 24
- HEATING & AIR CONDITIONING/CONTROLS/EVAPO-
RATOR TEMPERATURE SENSOR - REMOVAL).
Perform BODY VERIFICATION TEST.
No
>> The condition that caused this DTC to set is currently not
present. Inspect the related wiring harness for a possible intermittent condition.
Perform BODY VERIFICATION TEST.
HEATING & AIR CONDITIONING - ELECTRICAL DIAGNOSTICS 24 - 25