9871 TRUNK LATCH ACTUATOR LOCK CONTROL CIRCUIT SHORT TO B(+) (CONTINUED)
2.
Trunk Latch Actuator Lock Control Circuit For Short To B(+)
Turn the ignition off.
Disconnect the Power Top Control Module C1 harness connector.
Note: Check connectors — Clean/repair as necessary.
Turn the ignition on.
Measure the voltage between ground and the Trunk Latch Actuator
Lock Control circuit.
Is the voltage above 1.0 volts?
Yes
>> Repair the Trunk Latch Actuator Lock Control circuit for a
short to B(+).
Perform POWER TOP CONTROL MODULE VERIFICA-
TION TEST.
No
>> Go To 3
3.
Trunk Latch Actuator
Turn the ignition off.
Reconnect the Trunk Latch Assembly C2 harness connector.
Measure the resistance between the Trunk Latch Actuator Unlock Con-
trol circuit and the Trunk Latch Actuator Lock Control circuit from the
Power Top Control Module C1 harness connector.
Is the resistance between 3.0 - 7.0 ohms?
Yes
>> Replace the Power Top Control Module.(Refer to 8 -
ELECTRICAL/ELECTRONIC
POWER TOP CONTROL MODULE - REMOVAL).
Perform POWER TOP CONTROL MODULE VERIFICA-
TION TEST.
No
>> Go To 4