Chrysler 2005 Crossfire SRT6 Service Manual page 3684

Table of Contents

Advertisement

23 - 136
CONVERTIBLE TOP
9841 HYDRAULIC SOLENOID S4 SUPPLY VOLTAGE CIRCUIT OPEN/SHORT TO B(+) (CONTINUED)
2.
Hydraulic Solenoid S4 Supply Voltage circuit For Short To B(+)
Turn the ignition off.
Disconnect the Power Top Control Module C2 harness connector.
Note: Check connectors — Clean/repair as necessary.
Turn the ignition on.
Measure the voltage of the Hydraulic Solenoid S4 Supply Voltage cir-
cuit at the Power Top Control Module C2 harness connector.
Is the voltage below 1.0 volts?
Yes
>> Go To 3
No
>> Repair the Hydraulic Solenoid S4 Supply Voltage circuit for
a short to B(+).
Perform POWER TOP CONTROL MODULE VERIFICA-
TION TEST.
3.
Hydraulic Solenoid S4
With the ignition off.
Measure the resistance between the Hydraulic Solenoid S4 Supply
Voltage circuit and the Hydraulic Solenoid S3/S4 Ground circuit from
the Power Top Control Module C2 harness connector.
Is the resistance between 6.0 - 15.0 ohms?
Yes
>> Replace the Power Top Control Module.(Refer to 8 -
ELECTRICAL/ELECTRONIC
POWER TOP CONTROL MODULE - REMOVAL).
Perform POWER TOP CONTROL MODULE VERIFICA-
TION TEST.
No
>> Go To 4
CONTROL
MODULES/
ZH

Advertisement