Chrysler 2005 Crossfire SRT6 Service Manual page 3673

Table of Contents

Advertisement

ZH
9821 HYDRAULIC SOLENOID S2 SUPPLY VOLTAGE CIRCUIT OPEN/SHORT TO B(+) (CONTINUED)
5.
Open Hydraulic Solenoid S1/S2 Ground circuit
With the ignition off.
Measure the resistance of the Hydraulic Solenoid S1/S2 Ground circuit
from the Power Top Control Module C2 harness connector to the
Hydraulic Solenoid S2 harness connector.
Is the resistance below 5.0 ohms?
Yes
>> Replace the Power Top Hydraulic Assembly.(Refer to 23 -
BODY/CONVERTIBLE TOP/HYDRAULIC PUMP MOTOR
- REMOVAL).
Perform POWER TOP CONTROL MODULE VERIFICA-
TION TEST.
No
>> Repair the Hydraulic Solenoid S1/S2 Ground circuit for an
open.
Perform POWER TOP CONTROL MODULE VERIFICA-
TION TEST.
6.
PTCM
Turn the ignition off.
Measure the resistance between ground and the Hydraulic Solenoid
S1/S2 Ground circuit by backprobing the Power Top Control Module
C2 harness connector.
Is the resistance below 5.0 ohms?
Yes
>> Repair the Hydraulic Solenoid S1/S2 Ground circuit for an
open.
Perform POWER TOP CONTROL MODULE VERIFICA-
TION TEST.
No
>> Replace the Power Top Control Module.(Refer to 8 -
ELECTRICAL/ELECTRONIC
POWER TOP CONTROL MODULE - REMOVAL).
Perform POWER TOP CONTROL MODULE VERIFICA-
TION TEST.
CONTROL
MODULES/
CONVERTIBLE TOP 23 - 125

Advertisement

Table of Contents
loading

Table of Contents