9841 HYDRAULIC SOLENOID S4 SUPPLY VOLTAGE CIRCUIT OPEN/SHORT TO B(+) (CONTINUED)
• When Monitored: With the ignition on, the Power Top Control Module (PTCM) continuously senses the
voltage on the Hydraulic Solenoid S4 Supply Voltage circuit.
• Set Condition: When the PTCM senses B(+) on the Hydraulic Solenoid S4 Supply Voltage circuit.
POWER TOP HYDRAULIC ASSEMBLY)
OPEN HYDRAULIC SOLENOID S4 SUPPLY VOLTAGE CIRCUIT
HYDRAULIC SOLENOID S4 SUPPLY VOLTAGE CIRCUIT SHORT TO B(+)
OPEN HYDRAULIC SOLENOID S3/S4 GROUND CIRCUIT
POWER TOP CONTROL MODULE
Always perform the Pre-Diagnostic Troubleshooting procedure before proceeding.
Diagnostic Test
1.
Read DTCs
Turn the ignition on.
With the DRBIII , read Current DTCs.
Are both Hydraulic Solenoid S3/S4 Supply Circuit Open/Short
to B(+) DTCs set?
Yes
>> Go To 6
No
>> Go To 2
Possible Causes
CONVERTIBLE TOP 23 - 135