24 - 136
PLUMBING
REMOVAL
WARNING: REVIEW THE WARNINGS AND CAUTIONS IN THE FRONT OF THIS SECTION BEFORE PER-
FORMING THE FOLLOWING OPERATION.
1. Evacuate the refrigerant from the system. (Refer to
24 - HEATING & AIR CONDITIONING/PLUMBING
- STANDARD PROCEDURE).
2. Disconnect the negative battery cable.
3. Remove the accessory drive belt. (Refer to 7 -
COOLING/ACCESSORY DRIVE/DRIVE BELTS -
REMOVAL).
4. Raise and support the vehicle.
5. Remove the lower engine compartment panel.
6. Remove the three compressor bolts (1) attaching it
to the engine block.
7. Remove the bolts on the high side and the low side
pressure lines.
8. Disconnect the A/C harness connector from the
compressor.
INSTALLATION
1. Connect the A/C harness connector to the com-
pressor.
2. Install the bolts on the high side and the low side
pressure lines. Tighten to 23 N·m (17 ft. lbs.).
3. Install the A/C compressor then install the three
bolts (1). Tighten to 23 N·m (17 ft. lbs.).
4. Install the lower engine compartment panel.
5. Install the accessory drive belt. (Refer to 7 -
COOLING/ACCESSORY DRIVE/DRIVE BELTS -
INSTALLATION).
6. Connect the negative battery cable.
7. Charge the refrigerant to the system. (Refer to 24 -
HEATING & AIR CONDITIONING/PLUMBING -
STANDARD PROCEDURE).
PLUMBING
DESCRIPTION
The Coolant Circulation Pump is used to maintain a uniform flow of coolant through the Heater Core even at low
engine speeds and in the Residual Engine Heat Utilization mode (R.E.S.T.).