24 - 18
HEATING & AIR CONDITIONING - ELECTRICAL DIAGNOSTICS
RIGHT HEATER CORE TEMPERATURE SENSOR CIRCUIT (CONTINUED)
5.
MEASURE THE RESISTANCE OF THE SENSOR GROUND CIRCUIT
With the ignition off.
Measure the resistance of the Sensor Ground circuit from the A/C
Heater Control Module harness connector to the Heater Core Temper-
ature Sensor harness connector.
Is the resistance below 5.0 ohms?
Yes
>> Replace the A/C Heater Control Module. (Refer to 24 -
HEATING & AIR CONDITIONING/CONTROLS/HEATER
CONTROL - REMOVAL).
Perform BODY VERIFICATION TEST.
No
>> Repair the Sensor Ground circuit for an open.
Perform BODY VERIFICATION TEST.
6.
READ RIGHT HEATER CORE TEMPERATURE SENSOR VOLTAGE WITH DRB III
Turn the ignition off.
Disconnect the Heater Core Temperature Sensor harness connector.
Note: Check connector - Clean/repair as necessary.
Turn the ignition on.
With the DRB III , read the Right Heater Core Temperature Sensor
voltage.
Does the DRB III
VOLTS or greater?
Yes
>> Go to 7
No
>> Go to 9
display RIGHT HEATER CORE TEMP: 4.5
ZH