23 - 516
CONVERTIBLE TOP
REMOVAL - PUMP RESERVOIR
1. Disconnect the negative battery cable.
2. Remove the power top hydraulic assembly.(Refer
to 23 - BODY/CONVERTIBLE TOP/HYDRAULIC
PUMP MOTOR - REMOVAL).
3. Remove the reservoir plug (1) and drain fluid.
4. Remove the reservoir retaining clamp (3) and
remove reservoir (2) from the hydraulic pump
assembly.
INSTALLATION
INSTALLATION - HYDRAULIC PUMP MOTOR
1. Connect the hydraulic lines and retaining plate (2)
to the pump assembly (3). Torque the bolts (1) to
10 N·m (89 in. lbs.) using Loctite 270.
ZH