24 - 148
PLUMBING
It is a good practice to inspect all flexible hose refrigerant lines at least once a year to make sure they are in good
condition and properly routed.
1. Install the liquid line (1) to the condenser. Tighten
to 24 N·m (18 ft. lbs.).
2. Install the liquid line (1) to the receiver/dryer.
Tighten to 17 N·m (12 ft. lbs.).
3. Install the front inner wheel well panel.
4. Install the left front wheel and tire assembly.
5. Charge the A/C system.(Refer to 24 - HEATING &
AIR CONDITIONING/PLUMBING - STANDARD
PROCEDURE).
SUCTION LINE
REMOVAL
WARNING: REVIEW THE WARNINGS AND CAUTIONS IN THE FRONT OF THIS SECTION BEFORE PER-
FORMING THE FOLLOWING OPERATION.