Chrysler 2005 Crossfire SRT6 Service Manual page 3696

Table of Contents

Advertisement

23 - 148
CONVERTIBLE TOP
9870 TRUNK LATCH ACTUATOR LOCK CONTROL CIRCUIT SHORT TO GROUND (CONTINUED)
2.
Trunk Latch Actuator Lock Control Circuit For Short To Ground
Turn the ignition off.
Disconnect the Power Top Control Module C1 harness connector.
Note: Check connectors — Clean/repair as necessary.
Measure the resistance between ground and the Trunk Latch Actuator
Lock Control circuit.
Is the resistance below 100 kohms?
Yes
>> Repair the Trunk Latch Actuator Lock Control circuit for a
short to ground.
Perform POWER TOP CONTROL MODULE VERIFICA-
TION TEST.
No
>> Replace the Power Top Control Module.(Refer to 8 -
ELECTRICAL/ELECTRONIC
POWER TOP CONTROL MODULE - REMOVAL).
Perform POWER TOP CONTROL MODULE VERIFICA-
TION TEST.
CONTROL
MODULES/
ZH

Advertisement

Table of Contents
loading

Table of Contents