9811 HYDRAULIC SOLENOID S1 SUPPLY VOLTAGE CIRCUIT OPEN/SHORT TO B(+) (CONTINUED)
5.
Open Hydraulic Solenoid S1/S2 Ground circuit
With the ignition off.
Measure the resistance of the Hydraulic Solenoid S1/S2 Ground circuit
from the Power Top Control Module C2 harness connector to the
Hydraulic Solenoid S1 harness connector.
Is the resistance below 5.0 ohms?
Yes
>> Replace the Power Top Hydraulic Assembly.(Refer to 23 -
BODY/CONVERTIBLE TOP/HYDRAULIC PUMP MOTOR
- REMOVAL).
Perform POWER TOP CONTROL MODULE VERIFICA-
TION TEST.
No
>> Repair the Hydraulic Solenoid S1/S2 Ground circuit for an
open.
Perform POWER TOP CONTROL MODULE VERIFICA-
TION TEST.
6.
PTCM
Turn the ignition off.
Measure the resistance between ground and the Hydraulic Solenoid
S1/S2 Ground circuit by backprobing from the Power Top Control Mod-
ule C2 harness connector.
Is the resistance below 5.0 ohms?
Yes
>> Repair the Hydraulic Solenoid S1/S2 Ground circuit for an
open.
Perform POWER TOP CONTROL MODULE VERIFICA-
TION TEST.
No
>> Replace the Power Top Control Module.(Refer to 8 -
ELECTRICAL/ELECTRONIC
POWER TOP CONTROL MODULE - REMOVAL).
Perform POWER TOP CONTROL MODULE VERIFICA-
TION TEST.