Call For Service Environment Sensor - Minolta magicolor 330 Service Manual

Minolta laser printer service manual
Table of Contents

Advertisement

Primary FIPS: Error Messages
3.35 - Error Message: Call for Service Environment Sensor
There is a problem with the Environment Sensor circuit.
Logic control on the MCU PWB detected an open Environment Sensor circuit.
Step
SUSPECT COMPONENTS
The following components are associated with this specific prob-
lem. One or more of these components may have failed partially or
completely. If you cannot isolate the problem using this FIP,
replace each component listed below, one at a time, until the prob-
lem disappears.
• Wiring and connectors linking the components
1
Replace the Temperature Sensor Assembly (RRP 9.88)
Does the error message still appear?
2
Replace the MCU PWB (RRP 9.123)
Does the error message still appear?
3-38
Actions and Questions
Yes
Go to step 2
Go to suspect
components
magicolor 330 - Base Engine Service Manual
No
Problem
solved
Problem
solved