Minolta magicolor 330 Service Manual page 507

Minolta laser printer service manual
Table of Contents

Advertisement

BD7 MCU PWB↔LVPS↔Fuser Assembly↔Oil Roll Assembly
The following table shows the signal names for this BD:
Signal Name
AC L
AC N
TEMP
FUSER EXIT PAPER SENSED (L) 5VDC
FUSER ASSEMBLY SENSED (L) 5VDC
OIL ROLL SENSED (L) 5VDC
NEW OIL ROLL SENSED (L) 5VDC
magicolor 330 - Base Engine Service Manual
AC Hot for the Heat Rods
AC Neutral for the Heat Rods
Analog signal from the Fuser Temperature Sensor
Signal from the Fuser Exit Sensor. Low=Actuated. High=Not actuated
Monitors the position of the Fuser Assembly. Low=Fuser in position.
High=Fuser not in position
Monitors the presence of the Oil Roll. Low=Oil Roll in position.
High=Oil Roll not in position
At power on, monitors the state of the Oil Roll. Low=New. High=Old
Wiring Diagrams and Signal Information
Description
12-17