5.1 - Light (Undertoned) Prints, continued
Step
FUSER INSPECTION
6
Inspect the image on the sheet of paper after it exits the Fuser Rolls.
Is the image light when it exits the Fuser?
1. Replace the Oil Roll Assembly (RRP 9.82).
2. Generate a dozen test print.
7
3. Inspect the image on the last sheet out.
Is the image density now normal as it exits the Fuser?
magicolor 330 - Base Engine Service Manual
Actions and Questions
Primary Fault Isolation Procedures
Yes
Go to step 7
Problem
Replace
Solved
Pressure
(RRP 9.83) and
the Heat Roll
(RRP 9.84)
No
the
Roll
5-5