RRP 9.77 Auger Assembly (PL8.1.40)
Removal
1. Remove the Transfer Assembly (RRP 9.71).
2. Remove 2nd BTR Assembly (RRP 9.75).
3. Remove the Fuser Drive Assembly (RRP 9.110).
4. Remove the two screws securing the IBT Rear Bracket to the rear of the printer frame and remove the
Bracket.
5. Remove the screw securing the Auger Drive Assembly to the printer frame (Figure 1).
6. Remove the screw securing the Auger Tube to the rear of the printer frame (Figure 2).
7. Remove the screw securing the Auger Assembly bracket to the rear of the printer frame (Figure 3).
8. Swing the bottom of the Auger Assembly out, then slide the Auger Assembly down and remove the
Assembly from the printer (Figure 4).
Replacement
1. Reinstall the Auger Assembly onto the printer (Figure 4).
2. Slide the Auger Assembly bracket into position at the rear of the printer frame and use one screw to
secure the bracket.
3. Use one screw to secure the Auger Tube to the rear of the printer frame.
4. Use one screw to secure the Auger Drive Assembly to the printer frame.
5. Reinstall the IBT Rear Bracket to the rear of the printer frame and use two screws to secure the
Bracket.
6. Reinstall the Fuser Drive Assembly (RRP 9.110).
7. Reinstall the 2nd BTR Assembly (RRP 9.75).
8. Reinstall the Transfer Assembly (RRP 9.71).