Minolta magicolor 330 Service Manual page 285

Minolta laser printer service manual
Table of Contents

Advertisement

RRP 9.68 Rotary Sensor (PL7.2.22)
Removal
1. Remove the duct for Developer Fan by first removing the Fan (RRP 9.122) then removing the screw
securing the duct to the printer frame and removing the duct.
2. Remove the screw securing the Rotary Sensor Plate to the printer frame and remove the Plate, along
with the attached Rotary Sensor, from the frame.
3. Disconnect P/J 58 from the Rotary Sensor.
4. Squeeze the three latches securing the Sensor to the Plate and remove the Sensor.
Replacement
1. Position the Rotary Sensor against the Rotary Sensor Plate.
2. Press the Sensor latches into the cutout in the Plate.
The Sensor snaps into place.
3. Reconnect P/J 58 to the Rotary Sensor.
4. Position the Rotary Plate against the printer frame so the Rotary Sensor is facing into the cutout in the
frame.
5. Realign the Plate so the screw hole and two positioning holes in the Plate line up with the screw hole
and two positioning pins on the printer frame.
6. Use one screw to secure the Rotary Sensor Plate to the printer frame.
7. Reinstall the duct for the Developer Fan and use one screw to secure the duct to the printer frame.
8. Reinstall the Developer Fan (RRP 9.122).
magicolor 330 - Base Engine Service Manual
Removal and Replacement Procedures
9-141

Advertisement

Table of Contents
loading

Table of Contents