RRP 9.96 Cleaner Cam Solenoid (PL9.4.23)
Removal
1. Remove the Main Fuser Assembly (RRP 9.81).
2. Place the Fuser Tray on a flat and stable work surface.
3. Remove the two screws securing the Fuser Rear Rail to the Fuser Tray and pull the Rail away from
Tray (Figure 1).
4. Disconnect P/J 62 from the Cleaner Cam Solenoid and free the wire from the wire clip that is attached
to the Input Bracket.
5. Remove the two screws securing the Input Bracket to the Fuser Tray and pull the Bracket away from
the Tray.
6. Remove the screw securing the Cleaner Cam Solenoid to the Fuser Tray and remove the Solenoid.
Replacement
1. Line up the positioning hole and screw hole in the Cleaner Cam Solenoid with the positioning tab and
screw hole in the Fuser Tray.
2. Reinstall the Cleaner Cam Solenoid onto the Fuser Tray and use one screw to secure the Solenoid to
the Tray.
Make sure the Solenoid arms rest on the Cam as shown in Figure 2.
3. Route the Solenoid wire harness through the hole in the Input Bracket.
4. Line up the end of the Cleaner Cam Assembly shaft with the hole in the Input Bracket and reinstall the
Bracket onto the Fuser Tray.
5. Use two screw to secure the Input Bracket to the Fuser Tray.
6. Reconnect P/J 62 to the Cleaner Cam Solenoid and secure the wire under the wire clip that is attached
to the Input Bracket.
7. Line up the positioning hole and screw holes in the Fuser Rear Rail with the positioning tab and screw
holes in the Fuser Tray.
8. Reinstall the Fuser Rear Rail onto the Fuser Tray and use two screws to secure the Rail to the Tray.
9. Reinstall the Main Fuser Assembly (RRP 9.81).
magicolor 330 - Base Engine Service Manual
Removal and Replacement Procedures
9-197