RRP 9.130 Fuser Entrance Sensor (PL9.4.4)
Removal
1. Remove the Fuser Assembly (RRP 9.80).
2. Remove the two screws securing the Horizontal Chute to the Fuser Tray and remove the Chute (Fig-
ure 1).
3. Remove the four screws securing the Bottom Cover to the Fuser Tray and remove the Cover.
4. Release the latches securing the Fuser Entrance Sensor Holder to the Fuser Tray and remove the
Holder (Figure 2).
5. Disconnect the P/J 117 from the Entrance Sensor.
6. Release the latches securing the Fuser Entrance Sensor to the Fuser Tray and remove the Sensor.
Replacement
1. Reinstall the Fuser Entrance Sensor by pressing the latches on the bottom of the Sensor into the holes
in the Fuser Tray.
The Sensor snaps into place.
2. Reconnect P/J 117 to the Fuser Entrance Sensor.
3. Reinstall the Fuser Entrance Sensor Holder by placing the Holder over the reinstalled Sensor, then
pressing the latches on the bottom of the Holder into the holes in the Fuser Tray.
The Holder snaps into place.
4. Reinstall the Bottom Cover onto the Fuser Tray and use four screws to secure the Cover.
5. Reinstall the Horizontal Chute onto the Fuser Tray and use two screws to secure the Chute.
6. Reinstall the Fuser Assembly (RRP 9.80).
magicolor 330 - Base Engine Service Manual
Removal and Replacement Procedures
9-265