RRP 9.89 Fuser Exit Sensor (PL9.2.25)
Removal
1. Remove the Main Fuser Assembly (RRP 9.81).
2. Raise the Upper Guide Assembly so it is out of the way.
3. Remove the screw securing the Lower Exit Guide to the Main Fuser Assembly.
4. Slide the Lower Exit Guide to the to free the three latches that are located under the Guide and remove
the Guide from the Main Fuser Assembly.
5. Disconnect P/J 75 from the Fuser Exit Sensor.
6. Squeeze the latches securing the Fuser Exit Sensor to the Main Fuser Assembly and remove the Sen-
sor.
Replacement
1. Position the Fuser Exit Sensor against the cutouts in the Main Fuser Assembly.
2. Press the Fuser Exit Sensor into the cutouts unit the latches snap into place.
3. Reconnect P/J 75 to the Fuser Exit Sensor.
4. Use a lightly sticky tape back the four Pressure Roll Fingers that are attached to the Lower Exit Guide.
5. Make sure the Fuser Exit Sensor Actuator is still in place on the Lower Exit Guide.
6. Press and hold the Fuser Exit Sensor Actuator while you reinstall the Lower Exit Guide.
7. Reinstall the Lower Exit Guide onto the Main Fuser Assembly by first positioning the Guide slightly to
the left of center, then sliding the Guide to the right so the three latches under the Guide engage the
three slots in the Main Fuser Assembly.
8. Release the Fuser Exit Sensor Actuator and check the action to make sure it moves smoothly and is
positioned between the arms of the Fuser Exit Sensor.
9. Remove the tape from the four Pressure Roll Fingers, make sure there is no tape residue left on the
Fingers and make sure they all ride on the surface of the Press Roll.
10. Use one screw to secure the Lower Exit Guide to the Main Fuser Assembly.
11. Lower the Upper Guide Assembly.
12. Reinstall the Main Fuser Assembly (RRP 9.81).