Using Gpi In - Yamaha RIVAGE PM10 Operation Manual

Hide thumbs Also See for RIVAGE PM10:
Table of Contents

Advertisement

MIDI/GPI  Using GPI IN
3
Lighting external LED indicators via GPI OUT1
CS-R10
DSP-R10
+5V
10
CPU
Caution
Be careful not to exceed a current of 75 mA at the OUT ports.
4
Lighting a lamp (100V AC) by switching the relay on an external device via
GPI OUT1
CS-R10
DSP-R10
+5V
10
CPU
Caution
Be careful not to exceed a current of 75 mA at the OUT ports.
5
Lighting a lamp (24V DC) by switching the relay on an external device via
GPI OUT8
CS-R10
DSP-R10
RLY_NO
CPU
RLY_C
+5V
GPO1
75mA max
+5V
100V AC
+
GPO1
75mA max
+
24V DC
(30V max)
1A max

Using GPI IN

You can use the GPI IN ports of the GPI connector to control the parameters of the RIVAGE PM10
system from an external device. For example, you could use an external switch to turn the RIVAGE
PM10 system's Talkback on/off, operate the Tap Tempo function, or switch scenes.
1.
Connect an external device to the GPI connector on the control surface
(CS-R10).
2.
Press the SETUP button on the menu bar to access the SETUP screen.
3.
Press the MIDI/GPI button to open the MIDI/GPI popup window.
This window includes several pages, which you can switch between using the tabs located at
the top of the window.