Basic Operations  Shut down (power-off procedure)

Shut down (power-off procedure)

Before you shut down the control surface, Yamaha recommends that you store the current status to
scene memory.
If you change the connection status of the components after the power is turned off, some settings,
such as patching, may be altered when you turn the power on again. For instructions on storing
scenes, see
"Storing a
scene"
(page
197).
NOTICE
If you turn off the power to the control surface without following the shutdown procedure, data inside
the built-in storage (including the current memory) may be damaged. Be sure to perform the shutdown
procedure to turn off the power to the control surface.
Be sure to turn off the power to the components in the following sequence:
Speaker system → I/O rack (RPio622) → DSP engine (DSP-R10) → Shutting down the control
surface (CS-R10) → Control surface (CS-R10)
1.
Press the [SYSTEM] key for two seconds or longer.
A message will ask you to confirm the shutdown operation.
2.
To shut down the control surface, press the OK button. To cancel shutdown,
press the CANCEL button.
3.
Wait until the LEDs on the panel turn off, the touch screens go dark, and the
POWER indicator lights orange.
4.
Turn off both power switches A and B on the rear panel.
Caution
If you plan to turn on the power to the control surface again, wait at least five seconds before switching
the power on. Otherwise, the unit may malfunction.
Even when the power switches are turned off, a small amount of current still flows through the unit. If
you plan not to use the unit for a long period of time, remove the power cords from the AC outlets.
On-screen user interface
This section explains various user interface components shown in the touch screens, and how to use
them.
Tabs
Tabs enable you to switch between multiple pages. Each tab indicates its page name.
Buttons
Buttons are used to execute specific functions, to switch parameters on or off, or to select one of
multiple choices. Buttons that perform on/off operations appear in solid colors while they are turned
on, and dark when turned off.
When you press a
button, a separate popup window will open, allowing you to make detailed
settings.
When you press a
button, a pull-down menu will appear.