Yamaha RIVAGE PM10 Operation Manual page 248

Hide thumbs Also See for RIVAGE PM10:
Table of Contents

Advertisement

Maintenance  Adjusting the faders (FADER CALIB)
2.
Press the MAINTENANCE button to access the MAINTENANCE popup window.
This window includes several pages, which you can switch between using the tabs located at
the top of the window.
3.
Press the FADER CALIB tab.
The FADER CALIBRATION screen will appear, which will enable you to adjust the faders.
4.
Select the tab for the desired fader calibration operation.
If the MOTOR DRIVE calibration tab is selected:
For the specified faders in the Channel Strip section and Master section, the motorized fader
movement will be automatically calibrated.
5.
Press the [SEL] key for each fader that you want to calibrate.
Faders for which a problem was detected in the fader settings at start-up will already be
selected.
6.
Press the START button.
The system starts optimizing the movement of the motorized faders. The corresponding [SEL]
keys will flash during calibration.
To cancel in the middle of calibration, press the STOP button. When optimization of the
motorized fader movement is complete, the [SEL] keys will go dark.
7.
When calibration is complete, press the FINISH button.
The calibration values will be saved in internal memory. If the [SEL] key lights and the color
bar becomes red, calibration has failed. Press the START button to perform calibration again.
248
CONTENTS
FUNCTION MAP
RIVAGE PM10 Operation Manual
FAQ

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents