Plug-ins  Controlling the parameters of a plug-in
[How INPUT ADJUST works]
Rupert Comp 754
Inversely change in tandem
INPUT GAIN
COMPRESSOR/LIMITTER SECTION
COMPRESSOR
INPUT
CIRCUIT
INPUT ADJUST
3
BLEND knob
Adjusts the dry/wet balance of the compressor/limiter.
4
METER SELECT switch
Selects the signal source of the meter as input level, output level, or gain reduction.
5
Meter
Indicates the signal source that you selected in 4.
6
COMPRESS IN switch
Switches the compressor on/off.
7
COMPRESS THRESHOLD knob
Adjusts the threshold of the compressor.
8
COMPRESS RECOVERY knob
Adjusts the release time of the compressor. With the AUTO setting, the release time changes
automatically in the range of 50 ms to 5 sec.
9
COMPRESS RATIO knob
Adjusts the ratio of the compressor.
)
COMPRESS GAIN knob
Adjusts the makeup gain of the compressor. This applies before the limiter stage.
!
LIMIT IN switch
Switches the limiter on/off.
@
LIMIT THRESHOLD knob
Adjusts the threshold of the limiter.
OUTPUT GAIN
LIMITTER
OUTPUT
CIRCUIT
IN
IN
#
LIMIT RECOVERY knob
Selects the release time of the limiter. With the AUTO setting, the release time changes
automatically in the range of 50 ms to 5 sec.
$
LIMIT ATTACK switch
Switches the attack time of the limiter. FAST: 2ms, SLOW: 3ms