Retrying Inspection by External Signal (Trigger Retry)
Measurement is repeated until all inspection items have been successfully scanned.
Retry inspection ends when any one of the following conditions is satisfied:
(1)
The scanning result of all inspection items is OK.
(2)
Trigger retry (this command) turns OFF.
(3)
The timeout time is exceeded.
Note
• This function can be used in Run Mode only.
Parameters
Execution
Command
IN7
IN6
IN5
1
0001100
Timing Chart
• When inspection is OK
Run Mode entered.
ON
RUN signal
OFF
IN0 to IN6 signals
0
ON
IN7 signal
OFF
ON
BUSY signal
OFF
ON
OR signal
OFF
ON
ACK signal
OFF
FQ2-S/CH User's Manual
for Communications Settings
IN4
IN3
IN2
0001100
IN5 ON after at least 5 ms
Retry starts
Scan
Scan
Scan
NG
NG
OK
Retry ends
ACK output time
Controlling Operation and Outputting Data with a Parallel Interface Sensor Data Unit
IN1
IN0
1 Set the IN0 to IN6 signals.
Setup Mode entered.
2 When IN5 is turned OFF > ON with
the BUSY signal OFF, trigger retry
inspection starts.
3 When retry inspection starts, the
BUSY signal turns ON.
4 When the overall judgment turns ON,
retry inspection ends and the BUSY
signal turns OFF.
5 After verifying that the BUSY signal
has turned ON > OFF, IN5 is turned
ON > OFF.
Input example
10001100
85