Commands to Set Status
SCENE or S
Change Scene Number
This command changes the scene number to use.
<Command Format>
C
S C E N E
<Response Format>
When the Command Is Processed Normally
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
<Parameter Descriptions>
Scene number
FQ2-S/CH User's Manual
for Communications Settings
or
R
Delimiter
Scene number (2 digits max.)
Space (0x20)
Specifies the scene number (0 to 31) to change to.
C
S
R
Delimiter
Scene number (2 digits max.)
Space (0x20)