Omron FQ2-S Series User Manual page 430

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

● Save Model Dictionary Data: 280F 0070C000
Saves the specified number of model dictionary data as a file to the SD card inserted in the Touch Finder.
The destination for model dictionary data is the following fixed directory on the SD card.
\Sensor name\DIC
Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
Response Format
MRC
SRC
(1 byte)
(1 byte)
28
0F
End Codes
End code (hex)
0000
FFFF
Parameter Descriptions
Model dictionary number Specifies the scene number (0 to 31) to be saved.
Model dictionary data file
name
Important
• If the specified file name already exists, this existing file will be overwritten.
• Do not turn off power to the Vision Sensor until there is a response.
428
Command Control
Vision Sensor command code
(4 bytes)
0070C000
MRES
SRES
(1 byte)
(1 byte)
End code
Description
Command execution ended normally.
Command execution ended in an error.
Specifies the file name when saving.
The file name extension (.dic) can be omitted.
Model dictio-
Model dictionary
nary number to
data file name
be saved
(4 to 64 bytes)
(4 bytes)
2 digits max.
64 characters
max.
Vision Sensor command code
(4 bytes)
0070C000
FQ2-S/CH User's Manual
for Communications Settings

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fq2-ch series

Table of Contents