● Save Image Data: 280F 00704000
Saves image data saved in the Sensor's memory by the logging function to the SD card inserted in the Touch
Finder as ifz data.
The destination for image data is the following fixed directory on the SD card.
\Sensor name\LOGIMAGE\Number*
*
Number is a five digit number starting from 00000. The images are saved in increments of 100 images for each number, and when there
are over 100 images, the directory with the next number is created.
Format
MRC
SRC
Vision Sensor command code
(1 byte)
(1 byte)
(4 bytes)
28
0F
00704000
Response Format
MRC
SRC
MRES
(1 byte)
(1 byte)
(1 byte)
28
0F
End code
End Codes
End code (hex)
Meaning
0000
Command execution ended normally.
FFFF
Command execution ended in an error.
Parameter Descriptions
Image data number
Specifies the number of the image data to be saved.
The maximum number of logged images is 20 (image data number: 0 to 19).
The image data number of the latest image is 0.
Image data file name
Specifies the image data file name when saving. (64 characters max.)
The file name extension (.ifz) can be omitted.
Important
• If the same file is specified as an existing file, the existing file will be overwritten.
• Do not turn off power to the Vision Sensor until there is a response.
FQ2-S/CH User's Manual
for Communications Settings
Image data file name
(4 to 64 bytes)
64 characters max.
SRES
Vision Sensor command code
(1 byte)
(4 bytes)
00704000
423