Omron FQ2-S Series User Manual page 203

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

Command (PLC to Sensor Controller)
First word in
Hexadeci-
Command Area
mal notation
+2
4000
+3
0070
+4
0001
+5
0000
+6
4D49
+7
4741
+8
4E45
+9
4D41
+10
2E45
+11
4649
+12
005A
+13
0000
Specifying Real Numbers
Specify 1,000 times the actual value to specify a real number.
In this input example, the lower limit (external reference number 137) of the measurement coordinate X of the
Search registered in Unit No. 1 is set to "123.4" in the inspection item data setting command.
First word in Command Area
+2 and +3 words
+4 and +5 words
+6 and +7 words
+8 and +9 words
Command (PLC to Sensor Controller)
First word in
Hexadeci-
Command Area
mal notation
+2
1020
+3
0050
+4
0001
+5
0000
+6
0089
+7
0000
+8
E208
+9
0001
FQ2-S/CH User's Manual
for Communications Settings
Bits
12 to 15
8 to 11
4 to 7
0100
0000
0000
0000
0000
0111
0000
0000
0000
0000
0000
0000
0100
1101
0100
0100
0111
0100
0100
1110
0100
0100
1101
0100
0010
1110
0100
0100
0110
0100
0000
0000
0101
0000
0000
0000
Description
Command code (1020 0050 hex)
Unit number 1 (0000 0001 hex)
External reference number 137 (0000 0089 hex)
Lower limit of measurement coordinate X: 123.4 (x 1,000: 123400 = 0001
E208 hex)
Bits
12 to 15
8 to 11
4 to 7
0001
0000
0010
0000
0000
0101
0000
0000
0000
0000
0000
0000
0000
0000
1000
0000
0000
0000
1110
0010
0000
0000
0000
0000
Description
0 to 3
0000
Command code
0000
0001
Image data No.
0000
1001
File Name (IMAGENAME.IFZ)
+6: MI(4D49)
0001
+7: GA(4741)
+8: NE(4E45)
0101
+9: MA(4D41)
0001
+10: .E(2E45)
+11: FI(4649)
0101
+12:
Z(005A)
1001
+13:
1010
0000
Description
0 to 3
0000
Command code
0000
0001
Unit No.
0000
1001
External reference number
0000
1000
Lower limit value of measure-
ment coordinate X
0001
Command Control
201

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fq2-ch series

Table of Contents