Load Calibration Data
This command loads calibration data that is stored on the SD card inserted in the Touch Finder as the specified
calibration number.
The source for calibration data is the following fixed directory on the SD card.
\Sensor name\CLB
The file name is not case sensitive. The file name extension can be omitted.
Command (PLC to Vision Sensor)
First word of com-
mand area
+2
+3
+4
+5
+6
+7
+8
:
+37
*1
Loads the files named Calibration_***.clb saved on the SD card. (***: Specified file number)
Response (Vision Sensor to PLC)
First word of
response area
+2
+3
+4
+5
246
Command Control
Bits
12 to 15
8 to 11
4 to 7
1010
0000
0000
0000
0000
0110
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
0000
:
:
0000
0000
0000
Bits
12 to 15
8 to 11
4 to 7
1010
0000
0000
0000
0000
0110
0000
0000
0000
0000
0000
0000
Description
0 to 3
0000
Command code
0000
0000
Calibration data number you want to load (0 to
31)
0000
0000
• EtherNet/IP, PROFI-
NET
0000
File number to load (0
*1
to 999)
0000
---
:
:
0000
Description
0 to 3
0000
Command code
The command code for which the response
0000
applies is stored.
0000
Response code
Command execution result
0000
0: OK, FFFFFFFF: NG
• PLC link
File name to load
64 characters max.
The file name exten-
sion (.clb) can be omit-
ted.
FQ2-S/CH User's Manual
for Communications Settings