Omron FQ2-S Series User Manual page 329

Hide thumbs Also See for FQ2-S Series:
Table of Contents

Advertisement

POSITIONDATA or PD
Set Image Adjustment Data
This command sets parameters from a position compensation item or filter item.
<Command Format>
Command
P
O
S
I
T
I
or
P
D
Command
Space
Space
(0x20)
(0x20)
Item
Space
number
(0x20)
<Response Format>
When the Command Is Processed Normally
O
K
CR
Delimiter
When the Command Is Not Processed Normally
E
R
CR
Delimiter
<Parameter Descriptions>
Inspection item number
External reference data
number
Setting value
FQ2-S/CH User's Manual
for Communications Settings
O
N
D
A
T
A
Space
(0x20)
External
Setting value
reference data
(4 digits max.)
Space
(0x20)
Specifies the item number of the position compensation item or of the filter item.
Specifies the external reference data number.
Section 9-2 External Reference Parameters
in Vision Sensor FQ2-S/CH Series User's Manual (Cat. No. Z337)
Specifies the set value.
Section 9-2 External Reference Parameters
in Vision Sensor FQ2-S/CH Series User's Manual (Cat. No. Z337)
External reference data
(4 digits max.)
Item
number
Space
Space
(0x20)
(0x20)
CR
Delimiter
Setting value
CR
Space
Delimiter
(0x20)
Command Control
327

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Fq2-ch series

Table of Contents