● Save Scene Group Data: 280F 00702000
This command saves all scene data as a file to the SD card inserted in the Touch Finder.
The destination for all scene data is the following fixed directory on the SD card.
\Sensor name\SGP
Format
MRC
SRC
Vision Sensor command code
(1 byte)
(1 byte)
(4 bytes)
28
0F
00702000
Response Format
MRC
SRC
MRES
(1 byte)
(1 byte)
(1 byte)
28
0F
End code
End Codes
End code (hex)
Meaning
0000
Command execution ended normally.
FFFF
Command execution ended in an error.
Parameter Descriptions
All scene data file name Specifies the all scene data file name to save.
The file name extension (.sgp) can be omitted.
Important
• If the specified file name already exists, this existing file will be overwritten.
• Do not turn off power to the Vision Sensor until there is a response.
FQ2-S/CH User's Manual
for Communications Settings
Save scene group number
(4 bytes)
2 digits max.
SRES
Vision Sensor command code
(1 byte)
(4 bytes)
00702000
All scene data file
name (4 to 64 bytes)
64 characters max.
Command Control